Bare Aluminium Annealed Binding Wire Tie Wire Price

Model NO.: aluminum wire
Material Shape: Round Wire
Range of Application: Construction
Certification: ISO9001, CCC, BV, Tis, TUV
Brand: Rmjt
Standard: ASTM A475, ASTM B498, BS183
OEM: Supported
Company Type: Manufacturer
Sample: Avalible
Inspection: SGS, BV or Others
Trademark: RMJT
Transport Package: Packaged in Coils or by Drum
Specification: 1mm-5mm
Origin: China
HS Code: 7605110000
Model NO.: aluminum wire
Material Shape: Round Wire
Range of Application: Construction
Certification: ISO9001, CCC, BV, Tis, TUV
Brand: Rmjt
Standard: ASTM A475, ASTM B498, BS183
OEM: Supported
Company Type: Manufacturer
Sample: Avalible
Inspection: SGS, BV or Others
Trademark: RMJT
Transport Package: Packaged in Coils or by Drum
Specification: 1mm-5mm
Origin: China
HS Code: 7605110000
Bare Aluminium Annealed Binding Wire Tie Wire Price

Aluminum annealed binding wire.
Wire Guage: 1SWG~19SWG
Diameter: 1mm~5.9mm
Type: Bare

1. Application
This product is used as hanging cable, drawing cable and installation for field line, electric appliances and instruments, electronic equipment and automatic devices for electric power, chemical and so on. It is specially soft, easily folded and movable, smooth and aging resistant, high pulse staring current resistant.
2. Standard 
 BS 6500, BS 6004, BS 6360, BS EN 50363, IEC 60227, DIN VDE 0281.

3. Specification
450/750V PVC Insulation building wire to BS 6360
Single Core PVC Insulated
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 1/1.13 0.6 2.8 14
1.5 1/1.38 0.7 3.3 20
1.5 7/0.50 0.7 3.4 20
2.5 1/1.78 0.8 3.9 33
2.5 7/0.67 0.8 4.2 34
4 1/2.25 0.8 4.4 51
4 7/0.85 0.8 4.8 51
6 1/2.76 0.8 4.9 67
6 7/1.04 0.8 5.4 71
10 1/3.57 1.0 6.4 110
10 7/1.35 1.0 6.8 120
16 1/4.50 1.0 7.3 170
16 7/1.70 1.0 8.0 180
25 7/2.14 1.2 9.8 285
35 19/1.53 1.2 11.0 380
50 19/1.78 1.4 13.0 510
70 19/2.14 1.4 15.0 715
95 19/2.52 1.6 17.0 990
120 37/2.03 1.6 19.0 1230
150 37/2.25 1.8 21.0 1510
185 37/2.52 2.0 23.5 1900
240 61/2.25 2.2 26.5 2490
300 61/2.52 2.4 29.5 3050
400 61/2.85 2.6 33.5 3900
500 61/3.20 2.8 37.0 4880

450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Single Core PVC Insulated
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx.net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 32/0.20 0.6 3.0 16
1.5 30/0.25 0.7 3.5 21
2.5 50/0.25 0.8 4.2 33
4 56/0.30 0.8 4.8 50
6 84/0.30 0.8 6.3 70
10 80/0.40 1.0 7.6 120
16 126/0.40 1.0 8.8 175
25 196/0.40 1.2 11.0 290
35 276/0.40 1.2 12.5 400
50 396/0.40 1.4 14.5 565
70 360/0.50 1.4 17.0 770
95 475/0.50 1.6 19.0 1010
120 608/0.50 1.6 21.0 1260
150 756/0.50 1.8 23.5 1580
185 925/0.50 2.0 26.0 1900
240 1221/0.50 2.2 29.5 2500

Reference No 6192y
Flat Twin wire BVVB
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 0.9 4.0*6.2 4.7*7.4 55
1.5 1/1.38 0.7 0.9 4.4*7.0 5.4*8.4 70
2.5 1/1.78 0.8 1.0 5.2*8.4 6.2*9.8 105
4 7/0.85 0.8 1.0 5.6*9.6 7.2*11.5 150
6 7/1.04 0.8 1.1 6.4*10.5 8.0*13.0 205
10 7/1.35 1.0 1.2 7.8*13.0 9.6*16.0 325
16 7/1.70 1.0 1.3 9.0*15.5 11.0*18.5 465

Reference No 6242y
Flat-Twin with Bare Earth-continuity Conductor
Size of conductor Nominal thickness of insulation mm Size of earth conductivity conductor no./mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 1/1.13 0.9 4.0*7.2 4.7*8.6 70
1.5 1/1.38 0.7 1/1.13 0.9 4.4*8.2 5.4*9.6 85
2.5 1/1.78 0.8 1/1.13 1.0 5.2*9.4 6.2*11.0 120
4 7/0.85 0.8 1/1.38 1.0 5.6*10.5 7.2*13.0 175
6 7/1.04 0.8 1/1.78 1.1 6.4*12.5 8.0*15.0 240
10 7/1.35 1.0 7/0.85 1.2 7.8*15.5 9.6*19.0 390
16 7/1.70 1.0 7/1.04 1.3 9.0*18 11.0*22.0 560

300/300V CU/PVC/PVC Sheathed Circular Light Flexible Cords to BS 6500
Reference No 2182Y  Twin Core
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires No./mm Upper Limit mm Upper Limit mm
0.5 16/0.20 0.5 0.6 4.8 6.0 36
0.75 24/0.20 0.5 0.6 5.2 6.4 45

CU/PVC/PVC Sheathed Circular Light Flexible Cords
Reference No 3183Y  Three Core
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross- sectional area mm2 Number and diameter of wires no/mm Lower Limit mm Upper Limit mm
0.75 24/0.20 0.6 0.8 6.4 8.0 74
1.0 32/0.20 0.6 0.8 6.8 8.4 86
1.25 40/0.20 0.7 0.9 7.6 9.4 104
1.5 30/0.25 0.7 0.9 8.0 9.8 120
2.5 50/0.25 0.8 1.1 9.6 12.0 180

4. About us
People's Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.

5. Certificate
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.

6. Customer Visit
 We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!

7. Contact us
Factory ADD: No. 13th, Yongding Road, Gongyi, Zhengzhou city, Henan Province, China.
TEL: +86-371-55632896
FAX: +86-371-55632837
Mobile: +86-13598020132 Bare Aluminium Annealed Binding Wire Tie Wire Price

Aluminum annealed binding wire.
Wire Guage: 1SWG~19SWG
Diameter: 1mm~5.9mm
Type: Bare

1. Application
This product is used as hanging cable, drawing cable and installation for field line, electric appliances and instruments, electronic equipment and automatic devices for electric power, chemical and so on. It is specially soft, easily folded and movable, smooth and aging resistant, high pulse staring current resistant.
2. Standard 
 BS 6500, BS 6004, BS 6360, BS EN 50363, IEC 60227, DIN VDE 0281.

3. Specification
450/750V PVC Insulation building wire to BS 6360
Single Core PVC Insulated
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 1/1.13 0.6 2.8 14
1.5 1/1.38 0.7 3.3 20
1.5 7/0.50 0.7 3.4 20
2.5 1/1.78 0.8 3.9 33
2.5 7/0.67 0.8 4.2 34
4 1/2.25 0.8 4.4 51
4 7/0.85 0.8 4.8 51
6 1/2.76 0.8 4.9 67
6 7/1.04 0.8 5.4 71
10 1/3.57 1.0 6.4 110
10 7/1.35 1.0 6.8 120
16 1/4.50 1.0 7.3 170
16 7/1.70 1.0 8.0 180
25 7/2.14 1.2 9.8 285
35 19/1.53 1.2 11.0 380
50 19/1.78 1.4 13.0 510
70 19/2.14 1.4 15.0 715
95 19/2.52 1.6 17.0 990
120 37/2.03 1.6 19.0 1230
150 37/2.25 1.8 21.0 1510
185 37/2.52 2.0 23.5 1900
240 61/2.25 2.2 26.5 2490
300 61/2.52 2.4 29.5 3050
400 61/2.85 2.6 33.5 3900
500 61/3.20 2.8 37.0 4880

450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Single Core PVC Insulated
Size of conductor Nominal thickness of insulation mm Mean overall diameter Upper limit mm Approx.net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires no./mm
1.0 32/0.20 0.6 3.0 16
1.5 30/0.25 0.7 3.5 21
2.5 50/0.25 0.8 4.2 33
4 56/0.30 0.8 4.8 50
6 84/0.30 0.8 6.3 70
10 80/0.40 1.0 7.6 120
16 126/0.40 1.0 8.8 175
25 196/0.40 1.2 11.0 290
35 276/0.40 1.2 12.5 400
50 396/0.40 1.4 14.5 565
70 360/0.50 1.4 17.0 770
95 475/0.50 1.6 19.0 1010
120 608/0.50 1.6 21.0 1260
150 756/0.50 1.8 23.5 1580
185 925/0.50 2.0 26.0 1900
240 1221/0.50 2.2 29.5 2500

Reference No 6192y
Flat Twin wire BVVB
Size of conductor Nominal thickness of insulation mm Nominal thickness of sheath mm Mean overall dimensions Approx. net weight per km kg
Nominal cross-sectional area mm2 Number and diameter of wires mm Lower limit mm Upper limit mm
1.0 1/1.13 0.6 0.9 4.0*6.2 4.7*7.4 55
1.5 1/1.38 0.7 0.9 4.4*7.0 5.4*8.4 70
2.5 1/1.78 0.8 1.0 5.2*8.4 6.2*9.8 105
4 7/0.85 0.8 1.0 5.6*9.6 7.2*11.5 150
6 7/1.04 0.8 1.1 6.4*10.5 8.0*13.0 205
10 7/1.35 1.0 1.2 7.8*13.0 9.6*16.0 325
16 7/1.70 1.0 1.3 9.0*15.5 11.0*18.5 465

Reference No 6242y
Flat-Twin with Bare Earth-continuity Conductor