Model NO.: aluminum wire
Material Shape: Round Wire
Range of Application: Construction
Certification: ISO9001, CCC, BV, Tis, TUV
Brand: Rmjt
Standard: ASTM A475, ASTM B498, BS183
OEM: Supported
Company Type: Manufacturer
Sample: Avalible
Inspection: SGS, BV or Others
Trademark: RMJT
Transport Package: Packaged in Coils or by Drum
Specification: 1mm-5mm
Origin: China
HS Code: 7605110000
Model NO.: aluminum wire
Material Shape: Round Wire
Range of Application: Construction
Certification: ISO9001, CCC, BV, Tis, TUV
Brand: Rmjt
Standard: ASTM A475, ASTM B498, BS183
OEM: Supported
Company Type: Manufacturer
Sample: Avalible
Inspection: SGS, BV or Others
Trademark: RMJT
Transport Package: Packaged in Coils or by Drum
Specification: 1mm-5mm
Origin: China
HS Code: 7605110000
Bare Aluminium Annealed Binding Wire Tie Wire PriceAluminum annealed binding wire.
Wire Guage: 1SWG~19SWG
Diameter: 1mm~5.9mm
Type: Bare
1. Application
This product is used as hanging cable, drawing cable and installation for field line, electric appliances and instruments, electronic equipment and automatic devices for electric power, chemical and so on. It is specially soft, easily folded and movable, smooth and aging resistant, high pulse staring current resistant.
2. StandardÂ
 BS 6500, BS 6004, BS 6360, BS EN 50363, IEC 60227, DIN VDE 0281.
3. Specification
450/750V PVC Insulation building wire to BS 6360
Single Core PVC Insulated
Size of conductor | Nominal thickness of insulation mm | Mean overall diameter Upper limit mm | Approx. net weight per km kg | |
Nominal cross-sectional area mm2 | Number and diameter of wires no./mm | |||
1.0 | 1/1.13 | 0.6 | 2.8 | 14 |
1.5 | 1/1.38 | 0.7 | 3.3 | 20 |
1.5 | 7/0.50 | 0.7 | 3.4 | 20 |
2.5 | 1/1.78 | 0.8 | 3.9 | 33 |
2.5 | 7/0.67 | 0.8 | 4.2 | 34 |
4 | 1/2.25 | 0.8 | 4.4 | 51 |
4 | 7/0.85 | 0.8 | 4.8 | 51 |
6 | 1/2.76 | 0.8 | 4.9 | 67 |
6 | 7/1.04 | 0.8 | 5.4 | 71 |
10 | 1/3.57 | 1.0 | 6.4 | 110 |
10 | 7/1.35 | 1.0 | 6.8 | 120 |
16 | 1/4.50 | 1.0 | 7.3 | 170 |
16 | 7/1.70 | 1.0 | 8.0 | 180 |
25 | 7/2.14 | 1.2 | 9.8 | 285 |
35 | 19/1.53 | 1.2 | 11.0 | 380 |
50 | 19/1.78 | 1.4 | 13.0 | 510 |
70 | 19/2.14 | 1.4 | 15.0 | 715 |
95 | 19/2.52 | 1.6 | 17.0 | 990 |
120 | 37/2.03 | 1.6 | 19.0 | 1230 |
150 | 37/2.25 | 1.8 | 21.0 | 1510 |
185 | 37/2.52 | 2.0 | 23.5 | 1900 |
240 | 61/2.25 | 2.2 | 26.5 | 2490 |
300 | 61/2.52 | 2.4 | 29.5 | 3050 |
400 | 61/2.85 | 2.6 | 33.5 | 3900 |
500 | 61/3.20 | 2.8 | 37.0 | 4880 |
450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Single Core PVC Insulated
Size of conductor | Nominal thickness of insulation mm | Mean overall diameter Upper limit mm | Approx.net weight per km kg | |
Nominal cross-sectional area mm2 | Number and diameter of wires no./mm | |||
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5 | 30/0.25 | 0.7 | 3.5 | 21 |
2.5 | 50/0.25 | 0.8 | 4.2 | 33 |
4 | 56/0.30 | 0.8 | 4.8 | 50 |
6 | 84/0.30 | 0.8 | 6.3 | 70 |
10 | 80/0.40 | 1.0 | 7.6 | 120 |
16 | 126/0.40 | 1.0 | 8.8 | 175 |
25 | 196/0.40 | 1.2 | 11.0 | 290 |
35 | 276/0.40 | 1.2 | 12.5 | 400 |
50 | 396/0.40 | 1.4 | 14.5 | 565 |
70 | 360/0.50 | 1.4 | 17.0 | 770 |
95 | 475/0.50 | 1.6 | 19.0 | 1010 |
120 | 608/0.50 | 1.6 | 21.0 | 1260 |
150 | 756/0.50 | 1.8 | 23.5 | 1580 |
185 | 925/0.50 | 2.0 | 26.0 | 1900 |
240 | 1221/0.50 | 2.2 | 29.5 | 2500 |
Reference No 6192y
Flat Twin wire BVVB
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross-sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper limit mm | |||
1.0 | 1/1.13 | 0.6 | 0.9 | 4.0*6.2 | 4.7*7.4 | 55 |
1.5 | 1/1.38 | 0.7 | 0.9 | 4.4*7.0 | 5.4*8.4 | 70 |
2.5 | 1/1.78 | 0.8 | 1.0 | 5.2*8.4 | 6.2*9.8 | 105 |
4 | 7/0.85 | 0.8 | 1.0 | 5.6*9.6 | 7.2*11.5 | 150 |
6 | 7/1.04 | 0.8 | 1.1 | 6.4*10.5 | 8.0*13.0 | 205 |
10 | 7/1.35 | 1.0 | 1.2 | 7.8*13.0 | 9.6*16.0 | 325 |
16 | 7/1.70 | 1.0 | 1.3 | 9.0*15.5 | 11.0*18.5 | 465 |
Reference No 6242y
Flat-Twin with Bare Earth-continuity Conductor
Size of conductor | Nominal thickness of insulation mm | Size of earth conductivity conductor no./mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper limit mm | ||||
1.0 | 1/1.13 | 0.6 | 1/1.13 | 0.9 | 4.0*7.2 | 4.7*8.6 | 70 |
1.5 | 1/1.38 | 0.7 | 1/1.13 | 0.9 | 4.4*8.2 | 5.4*9.6 | 85 |
2.5 | 1/1.78 | 0.8 | 1/1.13 | 1.0 | 5.2*9.4 | 6.2*11.0 | 120 |
4 | 7/0.85 | 0.8 | 1/1.38 | 1.0 | 5.6*10.5 | 7.2*13.0 | 175 |
6 | 7/1.04 | 0.8 | 1/1.78 | 1.1 | 6.4*12.5 | 8.0*15.0 | 240 |
10 | 7/1.35 | 1.0 | 7/0.85 | 1.2 | 7.8*15.5 | 9.6*19.0 | 390 |
16 | 7/1.70 | 1.0 | 7/1.04 | 1.3 | 9.0*18 | 11.0*22.0 | 560 |
300/300V CU/PVC/PVC Sheathed Circular Light Flexible Cords to BS 6500
Reference No 2182Y Â Twin Core
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires No./mm | Upper Limit mm | Upper Limit mm | |||
0.5 | 16/0.20 | 0.5 | 0.6 | 4.8 | 6.0 | 36 |
0.75 | 24/0.20 | 0.5 | 0.6 | 5.2 | 6.4 | 45 |
CU/PVC/PVC Sheathed Circular Light Flexible Cords
Reference No 3183Y Â Three Core
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires no/mm | Lower Limit mm | Upper Limit mm | |||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 74 |
1.0 | 32/0.20 | 0.6 | 0.8 | 6.8 | 8.4 | 86 |
1.25 | 40/0.20 | 0.7 | 0.9 | 7.6 | 9.4 | 104 |
1.5 | 30/0.25 | 0.7 | 0.9 | 8.0 | 9.8 | 120 |
2.5 | 50/0.25 | 0.8 | 1.1 | 9.6 | 12.0 | 180 |
4. About us
People's Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2Â factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.
5. Certificate
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
6. Customer Visit
 We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
7. Contact us
Factory ADD: No. 13th, Yongding Road, Gongyi, Zhengzhou city, Henan Province, China.
TEL: +86-371-55632896
FAX: +86-371-55632837
Mobile: +86-13598020132 Bare Aluminium Annealed Binding Wire Tie Wire Price
Aluminum annealed binding wire.
Wire Guage: 1SWG~19SWG
Diameter: 1mm~5.9mm
Type: Bare
1. Application
This product is used as hanging cable, drawing cable and installation for field line, electric appliances and instruments, electronic equipment and automatic devices for electric power, chemical and so on. It is specially soft, easily folded and movable, smooth and aging resistant, high pulse staring current resistant.
2. StandardÂ
 BS 6500, BS 6004, BS 6360, BS EN 50363, IEC 60227, DIN VDE 0281.
3. Specification
450/750V PVC Insulation building wire to BS 6360
Single Core PVC Insulated
Size of conductor | Nominal thickness of insulation mm | Mean overall diameter Upper limit mm | Approx. net weight per km kg | |
Nominal cross-sectional area mm2 | Number and diameter of wires no./mm | |||
1.0 | 1/1.13 | 0.6 | 2.8 | 14 |
1.5 | 1/1.38 | 0.7 | 3.3 | 20 |
1.5 | 7/0.50 | 0.7 | 3.4 | 20 |
2.5 | 1/1.78 | 0.8 | 3.9 | 33 |
2.5 | 7/0.67 | 0.8 | 4.2 | 34 |
4 | 1/2.25 | 0.8 | 4.4 | 51 |
4 | 7/0.85 | 0.8 | 4.8 | 51 |
6 | 1/2.76 | 0.8 | 4.9 | 67 |
6 | 7/1.04 | 0.8 | 5.4 | 71 |
10 | 1/3.57 | 1.0 | 6.4 | 110 |
10 | 7/1.35 | 1.0 | 6.8 | 120 |
16 | 1/4.50 | 1.0 | 7.3 | 170 |
16 | 7/1.70 | 1.0 | 8.0 | 180 |
25 | 7/2.14 | 1.2 | 9.8 | 285 |
35 | 19/1.53 | 1.2 | 11.0 | 380 |
50 | 19/1.78 | 1.4 | 13.0 | 510 |
70 | 19/2.14 | 1.4 | 15.0 | 715 |
95 | 19/2.52 | 1.6 | 17.0 | 990 |
120 | 37/2.03 | 1.6 | 19.0 | 1230 |
150 | 37/2.25 | 1.8 | 21.0 | 1510 |
185 | 37/2.52 | 2.0 | 23.5 | 1900 |
240 | 61/2.25 | 2.2 | 26.5 | 2490 |
300 | 61/2.52 | 2.4 | 29.5 | 3050 |
400 | 61/2.85 | 2.6 | 33.5 | 3900 |
500 | 61/3.20 | 2.8 | 37.0 | 4880 |
450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Single Core PVC Insulated
Size of conductor | Nominal thickness of insulation mm | Mean overall diameter Upper limit mm | Approx.net weight per km kg | |
Nominal cross-sectional area mm2 | Number and diameter of wires no./mm | |||
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5 | 30/0.25 | 0.7 | 3.5 | 21 |
2.5 | 50/0.25 | 0.8 | 4.2 | 33 |
4 | 56/0.30 | 0.8 | 4.8 | 50 |
6 | 84/0.30 | 0.8 | 6.3 | 70 |
10 | 80/0.40 | 1.0 | 7.6 | 120 |
16 | 126/0.40 | 1.0 | 8.8 | 175 |
25 | 196/0.40 | 1.2 | 11.0 | 290 |
35 | 276/0.40 | 1.2 | 12.5 | 400 |
50 | 396/0.40 | 1.4 | 14.5 | 565 |
70 | 360/0.50 | 1.4 | 17.0 | 770 |
95 | 475/0.50 | 1.6 | 19.0 | 1010 |
120 | 608/0.50 | 1.6 | 21.0 | 1260 |
150 | 756/0.50 | 1.8 | 23.5 | 1580 |
185 | 925/0.50 | 2.0 | 26.0 | 1900 |
240 | 1221/0.50 | 2.2 | 29.5 | 2500 |
Reference No 6192y
Flat Twin wire BVVB
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross-sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper limit mm | |||
1.0 | 1/1.13 | 0.6 | 0.9 | 4.0*6.2 | 4.7*7.4 | 55 |
1.5 | 1/1.38 | 0.7 | 0.9 | 4.4*7.0 | 5.4*8.4 | 70 |
2.5 | 1/1.78 | 0.8 | 1.0 | 5.2*8.4 | 6.2*9.8 | 105 |
4 | 7/0.85 | 0.8 | 1.0 | 5.6*9.6 | 7.2*11.5 | 150 |
6 | 7/1.04 | 0.8 | 1.1 | 6.4*10.5 | 8.0*13.0 | 205 |
10 | 7/1.35 | 1.0 | 1.2 | 7.8*13.0 | 9.6*16.0 | 325 |
16 | 7/1.70 | 1.0 | 1.3 | 9.0*15.5 | 11.0*18.5 | 465 |
Reference No 6242y
Flat-Twin with Bare Earth-continuity Conductor
Size of conductor | Nominal thickness of insulation mm | Size of earth conductivity conductor no./mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires mm | Lower limit mm | Upper limit mm | ||||
1.0 | 1/1.13 | 0.6 | 1/1.13 | 0.9 | 4.0*7.2 | 4.7*8.6 | 70 |