Standard:
IEC60502, BS6346, VDE, AS/NZS, UL, etcÂ
The Rated Voltage(kv):
1st  class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35Â
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 -Â 26/35
Application:
XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
TYPE |
NAME |
Main Application |
|
CU core |
AL core |
||
YJV/YJY |
YJLV/YJLY |
XLPE insulated,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground. |
YJV22/YJV23 |
YJLV22/YJLV23 |
XLPE insulated,steel tape armored, |
For laying indoor ,tunnel,canal and underground. |
YJV32/YJV33 |
YJLV32/YJLV33 |
XLPE insulated,thin steel wire armored, |
For laying in shaft,water underground will large difference of level. |
YJV42/YJV43 |
YJLV42/YJLV43 |
XLPE insulated,thick steel wire armored, |
For laying in water and seabed. |
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal SectionÂ
Area(mm2) :1.5 2.5 4Â 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Features:
1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground.Â
Specification
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
1x4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
1x6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
1x10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
1x16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
1x25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
1x35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
1x50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
1x70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
1x95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
1x120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
1x150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
1x185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
1x240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
1x300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
1x400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
1x500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm² | mm | mm | mm | mm | mm | mm |
2x1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 12.8 |
2x2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 13.6 |
2x4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 14.6 |
2x6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 16.5 |
2x10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.1 |
2x16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 19.9 |
2x25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 23.6 |
2x35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 25.8 |
2x50 | 8 | 1 | 1 | 1.6 | 1.9 | 29 |
2x70 | 9.4 | 1.1 | 1 | 2 | 2 .3 | 3.2 |
2x95 | 11 | 1.1 | 1.2 | 2.1 | 3 | 7.1 |
2x120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 40.5 |
2x150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
2x185 | 15.3 | 1.6 | 1.4 | 2.5 | 20.6 | 49.9 |
2x240 | 17.5 | 1.7 | 1.4 | 2.5 | 20.7 | 55.1 |
2x300 | 19.5 | 1.8 | 1.6 | 2.5 | 20.9 | 60.2 |
2x400 | 22.6 | 2 | 1.6 | 2.5 | 30.1 | 67.7 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness LED Outdoor Lighting,LED Tunnel Light,LED Flood Light Light Venus Electronics Factory , http://www.light-your-home.com |