Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant

Model NO.: 4x120+1x70mm2
Material Shape: Round Wire
Range of Application: Mine
Certification: ISO9001, CE, CCC, VDE
Brand: Jinshui
Max D.C Rresistance at 20°c: 0.158
Voltage: 400V
Jacket: Flame Retardant
Standard: IEC60502
Armour: Galvanized Steel Wire .
Trademark: JINSHUI
Transport Package: Drum
Specification: CE, ASTM, BS, IEC
Origin: P. R. China
HS Code: 8544492100
Model NO.: 4x120+1x70mm2
Material Shape: Round Wire
Range of Application: Mine
Certification: ISO9001, CE, CCC, VDE
Brand: Jinshui
Max D.C Rresistance at 20°c: 0.158
Voltage: 400V
Jacket: Flame Retardant
Standard: IEC60502
Armour: Galvanized Steel Wire .
Trademark: JINSHUI
Transport Package: Drum
Specification: CE, ASTM, BS, IEC
Origin: P. R. China
HS Code: 8544492100

Our company has been carrying out Chinese national standard GB 12706 and GB 12666.6(equivalent to IEC 60502 and IEC 60331)for PVC insulated power cable and fire resistant cable needed by domestic customer, and for foreign customers we can manufacture in accordance with BS, DIN and other countries, standards. In addition, we can design and manufacture PVC insulated power cable with special characteristics according to needs of customers.

No. Description Unit Data Offered by Bidder
1 Manufacture   Henan Jinshui Cable Group Co., LTD.
2 Cable name   Low voltage power cable
3 Standard   IEC60520
4 Specified voltage V 400
5 Conductor material   Copper
6 Phase Conductor size mm2 120
7 Numbers of wires/single wire diameter Nos./mm 24/2.52
8 Conductor D.C. resistance at 20ºC Ω/km 0.158
9 Insulation Material   XLPE
10 Insulation Thickness, approx. mm 1.2
11 Insulated conductor diameters, approx. mm 15.83
12 Neutral Conductor size mm2 70
13 Numbers of wires/single wire diameter Nos./mm 14/2.52
15 Conductor D.C. resistance at 20ºC Ω/km 0.276
16 Insulation Material   XLPE
17 Insulation Thickness, approx. mm 1.1
18 Insulated conductor diameters, approx. mm 12.83
19 Inner Liner material   PVC
20 Armour material   Galvanized Steel Wire
21 Armour wire numbers*single wire    50*2.5
22 Outer sheath material   Flame Retardant PVC
23 Outer sheath thickness, approx. mm 2.6
24 Diameter of complete cable, approx. mm                49.5
25 Weight Kg/km 7924
26 Packing length m 500
27 Packing type   wooden drum
28 Drum dimensions mm 2200*1100

Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant
Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant
Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant
Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant







 

 

Our company has been carrying out Chinese national standard GB 12706 and GB 12666.6(equivalent to IEC 60502 and IEC 60331)for PVC insulated power cable and fire resistant cable needed by domestic customer, and for foreign customers we can manufacture in accordance with BS, DIN and other countries, standards. In addition, we can design and manufacture PVC insulated power cable with special characteristics according to needs of customers.

No. Description Unit Data Offered by Bidder
1 Manufacture   Henan Jinshui Cable Group Co., LTD.
2 Cable name   Low voltage power cable
3 Standard   IEC60520
4 Specified voltage V 400
5 Conductor material   Copper
6 Phase Conductor size mm2 120
7 Numbers of wires/single wire diameter Nos./mm 24/2.52
8 Conductor D.C. resistance at 20ºC Ω/km 0.158
9 Insulation Material   XLPE
10 Insulation Thickness, approx. mm 1.2
11 Insulated conductor diameters, approx. mm 15.83
12 Neutral Conductor size mm2 70
13 Numbers of wires/single wire diameter Nos./mm 14/2.52
15 Conductor D.C. resistance at 20ºC Ω/km 0.276
16 Insulation Material   XLPE
17 Insulation Thickness, approx. mm 1.1
18 Insulated conductor diameters, approx. mm 12.83
19 Inner Liner material   PVC
20 Armour material   Galvanized Steel Wire
21 Armour wire numbers*single wire    50*2.5
22 Outer sheath material   Flame Retardant PVC
23 Outer sheath thickness, approx. mm 2.6
24 Diameter of complete cable, approx. mm                49.5
25 Weight Kg/km 7924
26 Packing length m 500
27 Packing type   wooden drum
28 Drum dimensions mm 2200*1100

Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant
Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant
Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant
Low Voltage Power Cable 4X120+1X70mm2 XLPE Insulation Armoured Flame Retardant







 

 

Solder Cup Waterproof D-Sub Connector

The Solder Cups D-sub connector, also known as Solder Cups D-sub connector , typically contains a pin layout of 9 pin, 15 pin, 25 pin, 37 pin & 50 pin positions housed in increasing shell sizes accordingly. They are available in both male (plug) and female (socket) variants with the male signal contacts/pins (current rating of 5A) spaced every 2.76mm in horizontal rows and the spacing of rows vertically at 2.84mm laid out half the distance between pins of existing rows.


IP66 IP67 Rated Waterproof D-Sub Panel Mount Solder Connectors
Harsh outdoor or indoor environments can destroy electronic equipment. Standard D-sub connectors are not intended to withstand contaminants such as water and dust. These waterproof solder cup connectors are available in male or female genders and DB9, DB15, DB25, and HD15 sizes. They will accommodate wire ranges from 30 - 20 AWG. Construction features gold plated brass contacts, nickel plated steel shells, and a silicone insulating ring. Maximum recommended panel thickness is 0.078".

Antenk offer a wide range of waterproof standard density and high density male and female high density D-Sub connectors solder cup with stamped and formed Contacts in cable mount used in a variety of demanding applications.


Antenk's Solder Cup D-Sub Connectors Stamped contacts

FEATURES

Solder cup d-subs available in industry sizes/positions

Low cost economy series.

Nickel shells have indents to provide grounding and additional retention.

Low cost & high performance, non-removable stamped contacts.

Optional mounting hardware available.


Antenk's SOLDER CUP D-SUB CONNECTORS Stamped contacts

MATERIALS

Shell: Steel, Tin or Nickel Plated

Insulator: Glass-filled thermoplastic. U.L. rated 94V-O

(230°C process temp)

Stamped contacts: Male pins - Brass | Female pins - Phosphor bronze

Plating: Gold flash on entire contact (contact us for other plating options)



Solder Cup Waterproof D-Sub Connector Stamped & Formed Contact, Solder Cup Waterproof D-Sub Connector Machined Contacts, Waterproof Panel Mount Solder Cup D-Sub Connector

ShenZhen Antenk Electronics Co,Ltd , https://www.antenkelec.com