Model NO.: 240mm2
Wire Core Material: Red Copper Wire
Certification: ISO
Model: AGRP
Brand: Jytop
Industrial: Electric Stations
Voltage Range: 3.6/6kv
Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
Color: Black,Red,Yellow,Blue,Brown,Green
Certificate: Ce, ISO 9001
Trademark: JYTOP
Transport Package: Package in Drum
Specification: 1~1000mm2
Origin: Zhengzhou, China
HS Code: 8544492100
Model NO.: 240mm2
Wire Core Material: Red Copper Wire
Certification: ISO
Model: AGRP
Brand: Jytop
Industrial: Electric Stations
Voltage Range: 3.6/6kv
Standard: ASTM, AS/NZS, BS, CSA, DIN, IEC...
Color: Black,Red,Yellow,Blue,Brown,Green
Certificate: Ce, ISO 9001
Trademark: JYTOP
Transport Package: Package in Drum
Specification: 1~1000mm2
Origin: Zhengzhou, China
HS Code: 8544492100
Low Voltage LV Power Cable with XLPE Swa armoured Cable1. CE, ISO 9001 Certificaes
2. More than 23 years experiences
3. Professional Manufacturer with Factory located in Henan Province.
4. Quick response and fast delivery.
Â
6.35/11kV CU/XLPE/PVC(or PE) Power Cable
Â
1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic
polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
Â
 Chinese Type |
 Description |
Core qty | Conductors range |
YJV | Copper conductor, XLPE insulation, PVC outer sheath Power Cable | 1 or 3 | 25~800mm2 |
 YJY |
 Copper conductor, XLPE insulation, PE outer sheath Power Cable |
 1 or 3 |
 25~800mm2 |
ZA-YJV ZB-YJV ZC-YJV | Â Copper conductor, XLPE insulation flame-retardant Power Cable |
 1 or 3 |
 25~800mm2 |
WDZA-YJY WDZB-YJY WDZC-YJY | Â Copper conductor, XLPE insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable |
 1 or 3 |
 25~800mm2 |
2. Operating Characteristics
Rated voltage U0/U(Um): 6.35/11(12)kV
xlpe cable is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed; U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Â
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C The ambient temperature under installation should not be lower than: 0 °C.
The bending radius of cable is recommended as following:
For single core cable: not less than 20 times of the diameter of cable
For three core cable: not less than 15 times of the diameter of cable
Â
Â
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
Â
Â
4. Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008
We can produce above cables according to popular international standards such as ASTM,BS,DIN,NF &AS/NZ also.
Â
Â
5. Main technical data
5.1 Main technical data of 6.35/11KV, Single core, Copper conductor, XLPE insulated, and PVC or PE sheath cable
Â
CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/PVC or PE
 Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km) |
1x25mm2 | 3.4 | 0.12 | 1.8 | 20.3 | 0.727 |
1x35mm2 | 3.4 | 0.12 | 1.8 | 21.3 | 0.524 |
1x50mm2 | 3.4 | 0.12 | 1.8 | 22.4 | 0.387 |
1x70mm2 | 3.4 | 0.12 | 1.8 | 24.1 | 0.268 |
1x95mm2 | 3.4 | 0.12 | 1.8 | 25.7 | 0.193 |
1x120mm2 | 3.4 | 0.12 | 1.8 | 27.1 | 0.153 |
1x150mm2 | 3.4 | 0.12 | 1.8 | 28.7 | 0.124 |
1x185mm2 | 3.4 | 0.12 | 1.9 | 30.5 | 0.0991 |
1x240mm2 | 3.4 | 0.12 | 2.0 | 33.1 | 0.0754 |
1x300mm2 | 3.4 | 0.12 | 2.0 | 35.1 | 0.0601 |
1x400mm2 | 3.4 | 0.12 | 2.1 | 38.5 | 0.0470 |
1x500mm2 | 3.4 | 0.12 | 2.2 | 42.2 | 0.0366 |
1x630mm2 | 3.4 | 0.12 | 2.3 | 46.3 | 0.0283 |
1x800mm2 | 3.4 | 0.12 | 2.5 | 50.4 | 0.0221 |
Â
5.2 Main technical data of 6.35/11KV Single core, Copper conductor, XLPE insulated, copper wire screened and
PVC or PE sheath cable
CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/CWS/PVC or PE,
 Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Nominal diameter of copper wire(mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km) |
1x25mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 21.9 | 0.727 |
1x35mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 22.9 | 0.524 |
1x50mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 24.0 | 0.387 |
1x70mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 25.7 | 0.268 |
1x95mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 27.3 | 0.193 |
1x120mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 28.7 | 0.153 |
1x150mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 30.3 | 0.124 |
1x185mm2 | 3.4 | 0.12 | 0.9 | 1.9 | 32.1 | 0.0991 |
1x240mm2 | 3.4 | 0.12 | 0.9 | 2.0 | 34.7 | 0.0754 |
1x300mm2 | 3.4 | 0.12 | 0.9 | 2.1 | 36.9 | 0.0601 |
1x400mm2 | 3.4 | 0.12 | 0.9 | 2.2 | 40.3 | 0.0470 |
1x500mm2 | 3.4 | 0.12 | 0.9 | 2.3 | 44.2 | 0.0366 |
1x630mm2 | 3.4 | 0.12 | 0.9 | 2.4 | 48.0 | 0.0283 |
1x800mm2 | 3.4 | 0.12 | 0.9 | 2.5 | 52.0 | 0.0221 |
Â
5.3 Main technical data of 6.35/11KV, three cores, Copper conductor, XLPE insulated, and PVC or PE sheath cable.
CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/PVC or PE
 Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km) |
3x25mm2 | 3.4 | 0.10 | 2.2 | 40.9 | 0.727 |
3x35mm2 | 3.4 | 0.10 | 2.3 | 43.3 | 0.524 |
3x50mm2 | 3.4 | 010 | 2.4 | 45.9 | 0.387 |
3x70mm2 | 3.4 | 0.10 | 2.5 | 49.8 | 0.268 |
3x95mm2 | 3.4 | 0.10 | 2.6 | 53.6 | 0.193 |
3x120mm2 | 3.4 | 0.10 | 2.7 | 56.8 | 0.153 |
3x150mm2 | 3.4 | 0.10 | 2.8 | 60.6 | 0.124 |
3x185mm2 | 3.4 | 0.10 | 2.9 | 64.3 | 0.0991 |
3x240mm2 | 3.4 | 0.10 | 3.1 | 69.9 | 0.0754 |
3x300mm2 | 3.4 | 0.10 | 3.3 | 74.6 | 0.0601 |
3x400mm2 | 3.4 | 0.10 | 3.5 | 82.2 | 0.0470 |
 Low Voltage LV Power Cable with XLPE Swa armoured Cable
1. CE, ISO 9001 Certificaes
2. More than 23 years experiences
3. Professional Manufacturer with Factory located in Henan Province.
4. Quick response and fast delivery.
Â
6.35/11kV CU/XLPE/PVC(or PE) Power Cable
Â
1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic
polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
Â
 Chinese Type |
 Description |
Core qty | Conductors range |
YJV | Copper conductor, XLPE insulation, PVC outer sheath Power Cable | 1 or 3 | 25~800mm2 |
 YJY |
 Copper conductor, XLPE insulation, PE outer sheath Power Cable |
 1 or 3 |
 25~800mm2 |
ZA-YJV ZB-YJV ZC-YJV | Â Copper conductor, XLPE insulation flame-retardant Power Cable |
 1 or 3 |
 25~800mm2 |
WDZA-YJY WDZB-YJY WDZC-YJY | Â Copper conductor, XLPE insulation Low Smoke Halogen Free or Zero Halogen (LSHF or LSZH) flame-retardant Power Cable |
 1 or 3 |
 25~800mm2 |
2. Operating Characteristics
Rated voltage U0/U(Um): 6.35/11(12)kV
xlpe cable is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed; U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Â
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C The ambient temperature under installation should not be lower than: 0 °C.
The bending radius of cable is recommended as following:
For single core cable: not less than 20 times of the diameter of cable
For three core cable: not less than 15 times of the diameter of cable
Â
Â
3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
Â
Â
4. Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008
We can produce above cables according to popular international standards such as ASTM,BS,DIN,NF &AS/NZ also.
Â
Â
5. Main technical data
5.1 Main technical data of 6.35/11KV, Single core, Copper conductor, XLPE insulated, and PVC or PE sheath cable
Â
CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/PVC or PE
 Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km) |
1x25mm2 | 3.4 | 0.12 | 1.8 | 20.3 | 0.727 |
1x35mm2 | 3.4 | 0.12 | 1.8 | 21.3 | 0.524 |
1x50mm2 | 3.4 | 0.12 | 1.8 | 22.4 | 0.387 |
1x70mm2 | 3.4 | 0.12 | 1.8 | 24.1 | 0.268 |
1x95mm2 | 3.4 | 0.12 | 1.8 | 25.7 | 0.193 |
1x120mm2 | 3.4 | 0.12 | 1.8 | 27.1 | 0.153 |
1x150mm2 | 3.4 | 0.12 | 1.8 | 28.7 | 0.124 |
1x185mm2 | 3.4 | 0.12 | 1.9 | 30.5 | 0.0991 |
1x240mm2 | 3.4 | 0.12 | 2.0 | 33.1 | 0.0754 |
1x300mm2 | 3.4 | 0.12 | 2.0 | 35.1 | 0.0601 |
1x400mm2 | 3.4 | 0.12 | 2.1 | 38.5 | 0.0470 |
1x500mm2 | 3.4 | 0.12 | 2.2 | 42.2 | 0.0366 |
1x630mm2 | 3.4 | 0.12 | 2.3 | 46.3 | 0.0283 |
1x800mm2 | 3.4 | 0.12 | 2.5 | 50.4 | 0.0221 |
Â
5.2 Main technical data of 6.35/11KV Single core, Copper conductor, XLPE insulated, copper wire screened and
PVC or PE sheath cable
CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/CWS/PVC or PE,
 Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Nominal diameter of copper wire(mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km) |
1x25mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 21.9 | 0.727 |
1x35mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 22.9 | 0.524 |
1x50mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 24.0 | 0.387 |
1x70mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 25.7 | 0.268 |
1x95mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 27.3 | 0.193 |
1x120mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 28.7 | 0.153 |
1x150mm2 | 3.4 | 0.12 | 0.9 | 1.8 | 30.3 | 0.124 |
1x185mm2 | 3.4 | 0.12 | 0.9 | 1.9 | 32.1 | 0.0991 |
1x240mm2 | 3.4 | 0.12 | 0.9 | 2.0 | 34.7 | 0.0754 |
1x300mm2 | 3.4 | 0.12 | 0.9 | 2.1 | 36.9 | 0.0601 |
1x400mm2 | 3.4 | 0.12 | 0.9 | 2.2 | 40.3 | 0.0470 |
1x500mm2 | 3.4 | 0.12 | 0.9 | 2.3 | 44.2 | 0.0366 |
1x630mm2 | 3.4 | 0.12 | 0.9 | 2.4 | 48.0 | 0.0283 |
1x800mm2 | 3.4 | 0.12 | 0.9 | 2.5 | 52.0 | 0.0221 |
Â
5.3 Main technical data of 6.35/11KV, three cores, Copper conductor, XLPE insulated, and PVC or PE sheath cable.
CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/PVC or PE
 Size |
Nominal thickness of XLPE insulation(mm) |
Approx. thickness of copper tape screen (mm) |
Nominal thickness of PVC or PE(mm) |
Approx. overall diameter of finished cable(mm) |
Max. conductor D.C resistance @ 200C (Ω/km) |
3x25mm2 | 3.4 | 0.10 | 2.2 | 40.9 | 0.727 |
3x35mm2 | 3.4 | 0.10 | 2.3 | 43.3 | 0.524 |
3x50mm2 | 3.4 | 010 | 2.4 | 45.9 | 0.387 |
3x70mm2 | 3.4 | 0.10 | 2.5 | 49.8 | 0.268 |
3x95mm2 | 3.4 | 0.10 | 2.6 | 53.6 | 0.193 |
3x120mm2 | 3.4 | 0.10 | 2.7 | 56.8 | 0.153 |
3x150mm2 | 3.4 | 0.10 | 2.8 | 60.6 | 0.124 |
3x185mm2 | 3.4 | 0.10 | 2.9 | 64.3 | 0.0991 |
3x240mm2 | 3.4 | 0.10 | 3.1 | 69.9 | 0.0754 |
3x300mm2 | 3.4 | 0.10 | 3.3 | 74.6 | 0.0601 |
3x400mm2 | 3.4 | 0.10 | 3.5 | 82.2 | 0.0470 |
Â
Lithium Battery 2Cr11108,Marine Lithium Battery,Lithium Battery Smoke Alarms,Manganese Dioxide Lithium Battery
Jiangmen Hongli Energy Co.ltd , https://www.honglienergy.com