Original Meanwell Clg-150 Series Single Output Waterproof IP67 LED Driver

  • Model NO.: CLG-150
  • Output Type: DC
  • Color: White
  • Internal Structure: On-Off Type
  • Connection: Screw
  • Brand: Meanwell
  • Trademark: Meanwell
  • Specification: Universal
  • HS Code: 8504401400
  • Usage: Laptop, Switching, Mobile Phone, Game Player, Digital Camera, Phone, Display, LED Strip
  • Certification: TUV, RoHS, UL, ISO9001, CCC
  • Type: OEM
  • Power Source: Full-Bridge Type
  • Bluetooth Standard: 1.1
  • Size: 222.2*68*38.8mm
  • Transport Package: Paper Carton
  • Origin: Guangdong China (Mainland)

Original Meanwell CLG-150 Series Single Output Waterproof IP67 LED Driver Features:

1. Universal AC input / Full range (up to 295VAC)
2. Built-in active PFC function
3. High efficiency up to 89%
4. Protections: Short circuit / Over current / Over voltage / Over temperature
5. Cooling by free air convection
6. IP67 design for indoor or outdoor installations
7. Class 2 power unit
8. Pass LPS
9. 100% full load burn-in test
10. High reliability
11. Suitable for LED lighting and moving sign applications (Note.2)
12. Compliance to worldwide safety regulations for lighting
13. Suitable for dry / damp / wet locations
14. 3 years warranty

Original Meanwell CLG-150 Series Single Output Waterproof IP67 LED Driver Specifications:
 
MODEL CLG-150-12 CLG-150-15 CLG-150-20 CLG-150-24 CLG-150-30 CLG-150-36 CLG-150-48
OUTPUT DC VOLTAGE 12V 15V 20V 24V 30V 36V 48V
CONSTANT CURRENT REGION Note.4 9 ~12V 11.25 ~ 15V 15 ~ 20V 18 ~ 24V 22.5 ~ 30V 27 ~ 36V 36 ~ 48V
RATED CURRENT 11A 9.5A 7.5A 6.3A 5A 4.2A 3.2A
RATED POWER 132W 142.5W 150W 151.2W 150W 151.2W 153.6W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
VOLTAGE ADJ. RANGE Note.6 9 ~ 13V 13 ~ 17V 17 ~ 22V 22 ~ 27V 26 ~ 32V 31 ~ 41V 40 ~ 56V
CURRENT ADJ. RANGE Can be adjusted by internal potentiometer A type and C type only
5.5 ~ 11A 4.75 ~ 9.5A 3.75 ~ 7.5A 3.15 ~ 6.3A 2.5 ~ 5A 2.1 ~ 4.2A 1.6 ~ 3.2A
VOLTAGE TOLERANCE Note.3 ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 3000ms, 80ms/115VAC      500ms, 80ms/230VAC at full load
HOLD UP TIME (Typ.) 50ms / 230VAC       16ms / 115VAC at full load
INPUT VOLTAGE RANGE       Note.5 90 ~ 295VAC       127 ~ 417VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading>=75% at 115VAC/230VAC input and output loading>=75% at 277VAC input
EFFICIENCY (Typ.) 88% 88% 90% 90% 91% 91% 91%
AC CURRENT (Typ.) 2A / 115VAC       1A / 230VAC       0.68A / 277VAC
INRUSH CURRENT(max.) COLD START 65A(twidth=595μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT <1mA / 240VAC
PROTECTION OVER CURRENT (Typ.) Note.4 95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 13.5 ~ 17V 18 ~ 23V 23 ~ 28V 28 ~ 34V 33 ~ 39V 42 ~ 50V 59 ~ 70V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
ENVIRONMENT WORKING TEMP. -30 ~ +70ºC (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80ºC, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
SAFETY STANDARDS   Note.7 UL8750, CSA C22.2 No. 250.0-08, UL1012, CAN/CSA-C22.2 No. 107.1-01, UL879, CSA C22.2 No.207-M89, EN61347-1, EN61347-2-13 independent
(except for CLG-150 C type), UL60950-1, TUV EN60950-1,IP65 or IP67, J61347-1(except for CLG-150 C type), J61347-2-13 approved
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH
EMC EMISSION Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (>=75% load) ; EN61000-3-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
OTHERS MTBF 303.7K hrs min.    MIL-HDBK-217F (25ºC)
DIMENSION 222.2*68*38.8mm (L*W*H)(CLG-150-Blank/A/B)       229*68*38.8mm (L*W*H)(CLG-150-C)
PACKING 1.0Kg; 12pcs/13Kg/0.58CUFT(CLG-150-Blank/A/B)       1Kg; 12pcs/13Kg/0.96CUFT(CLG-150-C)
NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. A type and C type only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
 
 
 

CompactLogix Control Systems

Our CompactLogixâ„¢ and Compact GuardLogix® controllers use a common control engine with a common development environment to provide mid-range application control in an easy-to-use environment. Tight integration between the programming software, controller and I/O Modules reduces development time and cost at commissioning and during normal operation. This commonality provides cost-effective integration of a machine or safety application into a plant-wide control system because it integrates safety, motion, discrete and drive capabilities in a single controller.