Sagetail Yan Hanming: AI pain point and voice solution landing project for smart home

In 2013, it was called the first year of smart home, but until 2016, there was no real fire in smart homes. But we think that with the robot, this is the last key to open the smart home, the smart home may actually fire in the third quarter of 2017 or the fourth quarter.

There is several reasons for the lack of fire in smart homes: the cost of smart homes is too high, consumers are not aware of them, and the sense of interaction is not good enough.


Foxtail Technology Co., Ltd. COO Yan Hanming

Now, from the smart home, whether it is a single product or a system dispute, to the integration of smart home items and systems; from the whole society do not understand smart homes, almost all know smart homes; from personal, corporate investment to The input of the entire industry. The most important thing is that we can pass the robot and no longer interact with the mobile app and home. Realize the control of smart home through language, gestures and better ways. When this year's robots with AI are heavily introduced to the market, we think it is very likely that the last key of smart home will be opened this year.

We may have many application scenarios in the smart home field. The simplest application scenario is that I accept commands to control home appliances. This layer can be implemented with simple semantic processing. Such as turning on the lights, turning on the air conditioner, etc.

We will imagine a better use of the scene, he is not a direct semantic command, but to explore the needs of the owner after multiple rounds of interaction. For example, when you get home, you said that I am so tired today, my family is so hot. At this time, the robot will tell you, then I will sing a song for you, adjust the air conditioner to a comfortable temperature, and then you can say well. This is the service that the robot provides to you after multiple rounds of interaction.

Voice Solutions Landing Project

At present, our close cooperation projects include China Merchants Shekou, COFCO Real Estate, Greentown Real Estate, Greenland Real Estate, Longguang Real Estate, Jinke Real Estate, etc. Our company, Xiaobai Smart Plus, has successfully entered the model room of each cooperative real estate developer. And go to the hardcover standard way, landing in the direction of bulk shipment.

The hotel's son, Xiaobai Smart Plus, has entered the hotel rooms of the following hotel brands: Home Group, Heyi Group, Meihao Hotel Group, H Hotel, Platinum Group, Hong Kong Renaissance Group, etc.; will soon enter Wanda, Marriott, Starwood, etc. International brand.

In the field of smart devices, our company has accessed more than 50 brands, including well-known foreign LEGRAND, CRESTRON, CONTROL4, ABB, SMARTICSYS, etc. Domestically known, including Huawei, Ou Ruibo, Hedong, Op Lighting. Through various channels and business models, we carry out various joint promotion and sales.

Fiber Optic Patchcord

From the appearance, the "jumpers" of the board cards in the computer are small metal sticks (jumper posts) embedded on the motherboard, sound card, hard disk and other devices, and small clips (jumper clips) that are set on these metal sticks. The function of the jumper is to adjust the on-off relationship of different electrical signals on the device, and to adjust the working status of the device, such as determining the mainboard voltage, the master-slave relationship of the driver, and so on. When the jumper clip is put on two jumper posts at the same time, it means that the two jumper posts are connected. If only one or no jumper posts are put on, it means it is disconnected. It is very important to adjust the jumper. If it is jumped incorrectly, it may crash in some cases or even burn the entire device. Therefore, you must read the manual carefully when adjusting the jumper, and check the name of the jumper, the number of the jumper and the on-off relationship.
The jumpers on the motherboard generally include CPU setting jumpers, CMOS clear jumpers, and BIOS write prohibition jumpers. Among them, the CPU setting jumper is the most complicated. If the motherboard is relatively old, you must set the core voltage, FSB and frequency multiplier jumpers on the motherboard. According to the motherboard manual and CPU frequency, set the above corresponding jumpers. Normally, there is a set of jumpers corresponding to the CPU voltage on the motherboard, and each jumper corresponds to a voltage value. Find the appropriate voltage value, plug in a keycap to short it, and select this voltage value. In the same way, find the FSB jumper and multiplier jumper, and set the appropriate FSB and multiplier respectively. Note that only one jumper can be short-circuited in each group of jumpers.
The jumper here refers to the copper connecting wire, which is made of a standard jumper cable and connecting hardware. The jumper cable has copper cores ranging from two cores to eight cores. The connecting hardware is two 6-position or 8-position modular plugs. , Or they have one or more bare wire ends. Some jumpers have a modular plug at one end and an 8-position module slot at the other end, or are equipped with 100P wiring plugs, MICs, or module slots. Jumpers are used on the distribution frame to transfer various links, and can be used as a distribution frame or equipment connection cable. Both ends of the modular jumper are RJ45 connectors, adopt TIA/EIA-568A pin structure, and have a flexible plug-in design to prevent loosening and jamming. The length of the jumper is 1 foot (0.305 meters) to 500 feet (15.25 meters), the most commonly used are 3 feet, 5 feet, 7 feet and 10 feet. Modular jumpers are used in the work area and can also be used as jumpers in the wiring closet. In the small office network or home network DIY installation, the dual-computer interconnection jumper is often mentioned. This kind of jumper is not a standard jumper used in integrated wiring, but a special hardware device connection line. It is used when two PC computers are directly connected by twisted pair, or when two HUBs are to be connected through RJ45 ports. , You need crossover (commonly known as cross-connect wire, jumper). It follows a special connection sequence.

MTRJ Patchcord, ST Patchcord, FIN Patchcord, SC Patchcord, FC Patchcord, LC Patchcord

Shenzhen GL-COM Technology CO.,LTD. , https://www.szglcom.com