Taiwan media said the mainland set off a VR boom and consumed 40% of the world's helmets

Taiwan Media reported on July 20th that the mainland’s official policy support and private hot money have been invested in the development of the virtual reality (VR) market. The market research organization Canalys predicted that the mainland's 2016 VR market value will be only 1.5 billion yuan, and it will reach 55 billion yuan in 2020. International analysts believe that this year the world expects to ship 6.3 million VR helmets, 40% of which will be sold in mainland China.

According to the Taiwan Times news report on July 19th, Jaunt China, the world's best-known VR company, is optimistic about the prospects of the mainland movie market and the curiosity of the film's use of new VR technology. It has established a joint VR film and video experiment with the Digital Media Academy of Beijing Film Academy. The studio also announced the Jaunt VR video library on July 11 with Sony Interactive Entertainment (Shanghai), which has been launched on the PlayStation's mainland store. The first wave has 17 free-to-play programs, including 16 English-language programs, as well as the Shanghai Tourism Image Promotion film starring the mainland male Hu Ge.

Alibaba, Baidu, and Tencent, which lead the mainland's Internet, have also invested in VR technology in different ways, and have striven to become middlemen, creating platforms and content for VR helmets. Baidu has said that it will create the world's largest Chinese VR service through its iQiyi. At present, iQiyi has cooperated with VR manufacturers such as Beijing Baofeng and more than 300 partners to announce a newly developed application software that can make movies, games and head-mounted VR devices compatible. The company is also considering making live media concerts and shooting VR movies. It can also change the storyline of the movie based on changes in consumer preferences.

According to the report, when the United States focused on creating expensive VR advanced hardware devices, the mainland VR market tends to create entertainment experiences that drive consumer interest in VR. According to statistics, half of mainland players are interested in VR, and 30% of them are willing to spend at least 200 US dollars to purchase VR devices.

Surge Protection Device SPD

Product Description


SPD Surge Protective Device,Lightning Surge Protector
Surge Protection Device (SPD)


It is a device used to limiting instant surge voltage and discharge surge current, it at least including a non-linear component.

Surge protective Device Model Selection

With the impact of international information flow, the rapid development of microelectronic science and technology, communication, computer and automatic control technology, make the building start to go for high quality, high functional area, formed a new building style-intelligent building. As inside the intelligent building there are lot of information system, <<Building lightning protection design norm>> GB50057-94(2002 vision)(hereafter brief as <<lightning protection norm>>) put forward the relative requirement to install the surge protective device, to ensure the information system safely and stable running.
SPD essentially is a equipotential connection material, its model selection is according to the different lightning protection area, different lightning electromagnetic pulse critical and different equipotential connection position, decide which kind of SPD used in the area, to achieve the equipotential connection with the common earth electrode. Our statement will based on SPD's maximum discharge current Imax, continuous operating voltage Uc, protection voltage Up, alarm mode etc.
As per << Lightning Protection Norm>> item 6.4.4 stipulation "SPD must can withstand the expected lightning current flow and should confirm to the additional two requirements: the maximum clamp voltage during surge across, capable to extinguish the power frequency follow-on current after lightning current across." That is the value of SPD's max. clamp voltage add its induction voltage of two ends should be same with the system's basic insulation level and the equipment allowed max. surge voltage.

SPD for Power Supply System Series Selection Guide

The installation of SPD at each lightning protection zone, according to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category, its insulation withstand impulse voltage level can determine the selection of SPD. According to the standard of low voltage electrical appearance, make classification of electrical equipment in accordance with the over voltage category as signal level, loading level, distribution and control level, power supply level. Its insulation withstand impulse voltage level are:1500V,2500V,4000V,6000V. As per to the protected equipment installation position different and the different lightning current of different lightning protection zone, to determine the installation position of SPD for power supply and the break-over capacity.
The installation distance between each level SPD should not more than 10m, the distance between SPD and protected equipment should as short as possible, not more than 10m. If due to limitation of installation position, can't guarantee the installation distance, then need to install decoupling component between each level SPD, make the after class SPD can be protected by the prior class SPD. In the low voltage power supply system, connecting an inductor can achieve the decoupling purpose.
SPD for power supply system specification selection principle
Max. continuous operating voltage: bigger than protected equipment, the system's max. continuous operating voltage.
TT System: Uc≥1.55Uo (Uo is low voltage system to null line voltage)
TN System: Uc≥1.15Uo
IT System: Uc≥1.15Uo(Uo is low voltage system to line voltage)
Voltage Protection Level: less than the insulation withstand impulse voltage of protected equipment
Rated discharge current: determined as per to the lightning situation of the position installed and lightning protection zone.
SP1 Series

Normal Working Conditions
-Altitude not exceed 2000m
-Ambient air temperature:
Normal range: -5ºC~+40ºC
Extend range: -40ºC~+80ºC
-Relative Humidity: 30% - 90% under indoor temperature condition
- At the place without obviously shaking and shock vibration
- Non-explosion danger medium, non-corrosion gas and dust ( including conductive dust)

Classification

-As per Nominal Discharge Current:
5,10,20,30,40,60KA(8/20µs)
- As per Maximum continuous operating voltage:
275V,320V,385V,420V,440V,460V
- As per to poles
1P,1P+N,2P,3P,3P+N,4P
- As per auxiliary functions:
a. With remote signal output ( remote alarm function)
b. Without remote signal output

Selection Principle

- The continuous applied voltage on the two terminals of SPD should not more than the maximum continuous operating voltage Uc value;
- The voltage protection level Up of SPD should less than the maximum impulse withstand voltage of the protected equipment;
- As per to the different earthing system and protection mode to select the specification accordingly;

Product Features

1, built-in over-current overheating, temperature control circuit technology.

2, the module design, easy installation, online replacement.

3, low leakage current, fast response time, low residual voltage.

4, alarm indication device, green (normal) v red (fault).

Model/Technical Parameters WR-B60 WR-B80 WR-B100 WR-B120 WR-B150
Rated Operating Voltage Un (V ~) 220V 380V 220V 380V 220V 380V 220V 380V 220V 380V
Maximum Continuous Operating Voltage Uc (V ~) kV 385V 420V 385V 420V 385V 420V 385V 420V 385V 420V
Voltage Protection Level Up (V ~) kV ≤1.8≤2.2 ≤2.4≤2.5 ≤2.5≤3.2 ≤3.4≤3.7 ≤4.0≤4.5

Maximum Discharge

Current Imax(8/μ20μs)kA

60 80 100 120 150

Nominal Discharge

Current In(8/μ20μs)kA

30 40 60 80 100
Response Time <25 <100
L/N(mm²)The Cross Section Of L/N Line 16,25 16,25 16,25 16,25 25,35
PE (mm²)The Cross Section Of PE Line 16,25 25,35 25,35 25,35 35
Fuse or Switch (A) 63A 63A 63A,100A 63A,100A 63A,125A
The Line Section of Communication and Alarm (mm²) ≥ 1.5

Operating

Environment-C

(-40ºC~-+85ºC)
Relative humidity 25 ºC ≤95%
installation Standard Rail35mm
Material of Outer Covering Fiber Glass Reinforced Plastic

Surge Protector SPD,Surge Protection Device SPD,SPD

Wenzhou Korlen Electric Appliances Co., Ltd. , https://www.zjmannualmotorstarter.com