This standard refers to the use of the international standard IEC 400 (1987) "tubular fluorescent lamp holder and starter seat".
1 Subject content and scope of application
This standard specifies the technical requirements, test methods and inspection rules for tubular fluorescent lamp holders and starter seats (hereinafter referred to as lamp holders and bases, respectively). It is used to ensure the safety and interchangeability of the fluorescent lamp and the starter in the seat.
This standard is applicable to the lamp holder and the seat with protection class IP20 (the seat above the protection class should refer to the relevant test of GB7001), and it is used in places without dripping, dust-free and non-corrosive gas.
This standard applies to the lamp holder and the seat included in GB 13260. Other types of seats should also be used as reference.
2 Reference standard
GB 2828 batch-by-batch inspection sampling procedure and sampling table (for continuous batch inspection)
GB 2829 cycle check counting sampling program and sampling table (applicable to the inspection of the stability of the production process)
General safety requirements and tests for GB 7000 lamps
GB 7001 luminaire enclosure protection class classification
GB 13260 tubular fluorescent lamp holder and starter seat type and size
GB 13261 tubular fluorescent lamp holder and starter seat inspection gauge
ZB K74 011 General requirements and safety requirements for AC electronic ballasts for tubular fluorescent lamps
ZB K74 002 socket type lamp holder technical conditions
ZB K74 003 screw-type lamp holder technical conditions
3 terms
3.1 Elastic lamp holder: A pair of lamp holders fixedly mounted in the lighting device. The contact position of one or two lamp holders can be moved axially to compensate for the change of the length of the lamp tube and facilitate the loading and unloading of the lamp.
3.2 Inelastic lamp holders (also known as rigid lamp holders): A pair of mounting positions are fixed and do not rely on the movement of the contacts to compensate for changes in the length of the lamp or to mount the lamp holder.
3.3 Built-in lamp holder or stand: A seat specially designed for mounting inside the lamp.
3.4 Unprotected lamp holder or stand: Use additional means to provide a seat for protection against electric shock.
3.5 Stand-alone lamp holder or stand: A lamp holder or a stand that can be separated from the lighting device and can meet the necessary protection against electric shock.
4 Electrical parameter rating and maximum operating temperature
4.1 AC voltage RMS: no less than 125V for G 5 sockets, no higher than 250V; no less than 125V for other models, no higher than 1000V.
4.2 Current value: not less than 1A for G5 and G23 sockets; not less than 2A for other models.
4.3 Maximum working temperature: no more than 50 °C for G5 lamp holder; no more than 110 °C for G23 lamp holder; no more than 80 °C for other lamp holders.