PPI expansion module introduction:
Doing projects often encounter 200 PLC PPI port is not enough, Dalian Dejia launched PPI expansion module, you can expand a PPI port (only PPI protocol), use software and hardware without any changes, plug and play!
The PPI port address of the PPI expansion module is 2 (is fixed)
The protocol of the PPI port of the PPI expansion module is the same as the factory default setting of the S7-200 PLC. Both are PPI slave mode (point-to-point interface protocol).
Can connect Siemens smart700/1000 touch screen, can also connect Kunlun pass state, Bu Ke, Wei Lun and many other domestic brands touch screen, you can also connect Siemens USB-PPI, RS232-PPI programming cable for online programming (upload / download) or real-time monitoring .
The baud rate of PPI port of PPI expansion module is 187.5K, 19200, 9600.
Note: This setting is done by shorting the terminals at the bottom of the module. After the baud rate is set, it needs to be re-powered, and the power-on self-check will not enter the working state after 9 seconds.
(1), if not shorted (ie without any settings) The baud rate is 187.5K.
(2) The second terminal in the lower left row and the third terminal in the lower left row are short-circuited with wires, and the baud rate is 9600.
(3) Connect the second terminal in the lower left row and the fourth terminal in the lower left row with the wire and the baud rate is 19200.
The PPI expansion module requires an external 24V power supply: the 2nd terminal on the right of the upper row is connected with 24V positive, and the 3rd terminal on the right of the upper row is connected with 24V ground.
Second, introduction of Ethernet module CP243u
The S7-200 Ethernet module CP243u supports the following functions:
1) Connection to WinCC does not require OPC and can be directly connected to enhance communication stability.
2) You can use Siemens Prodave and VB to develop your own S7-200 upper software.
3) 4 upper computers can be connected at the same time.
4) With 2 communication channels, it can realize the communication functions between S7-200 and S7-1200, S7-300, S7-200 Smart and other PLCs.
5) Connect to the PLC via the PPI programming port of the Siemens S7-200 without occupying the module position.
Third, the actual solution
The following is the actual hardware connection diagram of PPI expansion module and Ethernet module CP243u, which can be fully utilized in actual engineering projects.
Here, the PPI expansion module adds a PPI port to be used as a program download program. It can also be connected to a touch screen, and can be connected in different ways according to the actual requirements and design.
This solution can be used in large-scale PLC networking. In addition, the S7-300 Ethernet module has the function of communication with the PLC, and the model is ETH-MPI (smartIE). It is connected to the MPI port of 300 and can be connected to s7-200/1200. PLC communication such as /300PN/200 smart, and SIMATIC Wonderful Panel (SMART LINE) are also very powerful.